2-6.

Cleaning and Disassembly of the IR Unit

(1)

Cleaning of the Scanner Rails

(2)

Cleaning of the Mirrors (1st/2nd/3rd)

(3)

Cleaning of the Lens

1. Remove the IR Right Cover and Original Glass.
2. Using a soft cloth dampened with alcohol, wipe
the Scanner Rails clean of dirt.
NOTE
• Lubricate the rails after cleaning.
4004D198AA
1. Remove the IR Right Cover and Original Glass.
2. Using a soft cloth dampened with alcohol, wipe
mirrors clean of dirt.
4004D199AA
1. Remove the IR Right Cover and Original Glass.
2. Remove eight screws and the optical cover.
4004D001AC
3. Using a soft cloth dampened with alcohol, wipe
the Lens clean of dirt.
4004D200AB
D-25