(3)
Web Take-Up Mechanism
• Oil is applied from the Web to the Oil Donor Roller.
• The Web is taken up by a motor.
• The Cleaning Web Drive Motor controls the amount of web taken up.
Web Take-Up Amount
Web Take-Up Roller
Controlled Part
M5
(4)
Web Slack Take-Up Control
• The slack in the Web is taken up by energizing the Cleaning Web Drive Motor.
• The Cleaning Web Drive Motor is energized for a given period of time when the Fusing
Roller remains stationary.
Operation Timing
0.125 mm per sec.
Control Signal
Energized
PJ4I-11~14
After a misfeed has been cleared
After the Web has been changed
M-92
Web
Cleaning Web Drive Motor (M5)
Deenergized WIRING DIAGRAM
Pulse Output
4004M053AB
2-E