Technical Data - Graco ProMix PD2K Operation

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Technical

Technical Data

Technical
Data
Data
Positive Displacement
Displacement
Positive
Positive
Displacement
Proportioner
Proportioner
Proportioner
Maximum fluid working
pressure:
AC1002 and AC3002 Air
Spray Systems
AC2002 and AC4002
Air-Assisted Spray
Systems
Maximum working air
pressure:
Air supply:
Air filter inlet size:
Air filtration for air logic
(user-supplied):
Air filtration for atomizing
air (user-supplied):
Mixing ratio range:
Fluids handled:
Viscosity range of fluid:
Fluid filtration
(user-supplied):
Maximum fluid flow:
Fluid outlet size:
External power supply
requirements:
Operating temperature
range:
Storage temperature
range:
Weight (approximate):
Sound data:
Wetted parts:
AC1002 and AC2002
AC4002
3A4486D
U.S.
U.S.
U.S.
300 psi
1500 psi
100 psi
85–100 psi
5 micron (minimum) filtration required; clean and dry air
30 micron (minimum) filtration required; clean and dry air
one or two component:
• solvent and waterborne paints
• polyurethanes
• epoxies
• acid catalyzed varnishes
• moisture sensitive isocyanates
800 cc/minute (depending on material viscosity)
90 - 250 Vac, 50/60 Hz, 7 amps maximum draw
15 amp maximum circuit breaker required
36 to 122°F
—4 to 158°F
195 lb
17–4PH, 303, 304 SST, Tungsten carbide (with nickel binder),
perfluoroelastomer; PTFE, PPS, UHMWPE
perfluoroelastomer; PTFE, PPS, UHMWPE
3/8 npt(f)
0.1:1 — 50:1, ±1%
20–5000 centipoise
100 mesh minimum
1/4 npt(m)
8 to 14 AWG power supply wire gauge
Less than 75 dB(A)
316 SST, 17–4PH SST, PEEK,
Technical Data
Metric
Metric
Metric
2.1 MPa, 21 bar
10.5 MPa, 105 bar
0.7 MPa, 7.0 bar
0.6–0.7 MPa, 6.0–7.0 bar)
2 to 50°C
—20 to 70°C
88 kg
115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents