Operation Using a Programmable Logic Controller (PLC)
Read Event
Event Info
Info
Read
Read
Event
Info
The Read Event Info command allows remote access to any of the last 200 events logged by the ProMix PD2K.
chronological index
The argument is the
most recent.
The date is returned as a four-byte packet with each byte holding a two-digit value for (from MSB to LSB) year, month,
day, and day of the week (Monday = 01).
The time is returned as a three-byte packet with each byte holding a two-digit value. Starting from the MSB, the first
byte can be ignored, then hour, minute, and second.
The event code is a four-character little endian ASCII string.
The example decoding algorithm provided above for the Alarm Code may be used for Events equivalently.
Example: Read back the fifth most recent event, which was a Setup Value(s) Changed (EC00) recorded on Tuesday
June 3, 2014 at 8:11 AM.
DCS Register
Register
Parameter Description
DCS
DCS
Register
Parameter
Parameter
DCS
Read Event Info
Command
Argument 0
Event Number
Acknowledge
Command
Acknowledged
Return 0
Event Date
Return 1
Event Time
Return 2
Event Code Char[3:0]
Read Grand
Grand Totals
Totals
Read
Read
Grand
Totals
The Read Grand Totals command allows remote access to the material grand total volume data. No arguments
are necessary for this command.
Example: Read current Grand Total usage data. A = 132 gal, B = 128 gal, A+B = 260 gal, Solvent = 11 gal
DCS
DCS Register
DCS
Register
Register
Parameter Description
Parameter
Parameter
DCS
Read Grand Totals
Command
Acknowledge
Command
Acknowledged
Return 0
Grand Total A Material
Return 1
Grand Total BMaterial
Return 2
Grand Total A+B
Return 2
Grand Total Solvent
58
of the events log, where 0 is the most recent event and 199 is the 200
Description
Data
Description
Data
Data
Type
Type
Type
uint32
uint32
uint32
uint32
uint32
uint32
Description
Description
Data
Data
Data
Type
Type
Type
uint32
uint32
uint32
uint32
uint32
uint32
Units
Value
Units
Units
Value
Value
NONE
16
NONE
4
NONE
2 = ACK
[YY:MM:DD-
0x0E060302 =
:DW]
[14:06:03:02]
[xx:HH:MM:SS]
0x080B0B =
[08:11:11]
NONE
0x30304345 = ['0',
'0', 'C', 'E']
Units
Units
Units
Value
Value
Value
NONE
22
NONE
2 = ACK
Gallons
132
Gallons
128
Gallons
260
Gallons
11
th
Range
Range
Range
0 - 16
0 - 199
0 - 4
N/A
N/A
N/A
Range
Range
Range
0 – 22
0 – 4
0 –
4,294,967,295
0 –
4,294,967,295
0 –
4,294,967,295
0 –
4,294,967,295