Graco ProMix PD2K Operation page 53

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Write Flush
Flush Sequence
Sequence
Write
Write
Flush
Sequence
The Write Flush Sequence command allows users to configure an entire flush sequence remotely. See
Flush Screen, page
79, for more details of flush sequence parameters. The return registers will echo the arguments
received.
Example: Configuring Flush Sequence 4 for Gun Purge Time = 10 sec, Initial Flush Volume = 125 cc, Final Flush
Volume = 250 cc, Wash Cycles = 1, Strokes per Cycle = 2.
DCS
DCS
DCS Register
Register
Register
Parameter Description
Parameter
Parameter
DCS
Write Flush Sequence
Command
Argument 0
Flush Sequence #
Argument 1
Gun Purge Time
Argument 2
Initial Flush Volume
Argument 3
Final Flush Volume
Argument 4
# Wash Cycles
Argument 5
Strokes per Wash Cycle
Acknowledge
Command Acknowledged
Return 0
Flush Sequence #
Return 1
Gun Purge Time
Return 2
Initial Flush Volume
Return 3
Final Flush Volume
Return 4
# Wash Cycles
Return 5
Strokes per Wash Cycle
3A4486D
Operation Using a Programmable Logic Controller (PLC)
Description
Description
Data
Data
Data
Type
Type
Type
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
uint32
Units
Units
Units
Value
Value
Value
NONE
3
NONE
4
NONE
10
NONE
125
NONE
250
NONE
1
NONE
2
NONE
2 = ACK
4
NONE
sec
10
cc
125
cc
250
NONE
1
2
NONE
Range
Range
Range
0 - 21
1 - 5
0 - 999
0 - 9999
0 - 9999
0 - 99
0 - 99
0 - 4
1 - 5
0 - 999
0 - 9999
0 - 9999
0 - 99
0 - 99
53