Purging - Graco ProMix PD2K Operation

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Purging

Purging
Purging
To purge one color and fill with a new color, see
Color Change, page
98.
Flush
Flush Mixed
Flush
Mixed
Mixed Material
Material
Material
To avoid fire and explosion, always ground
equipment and waste container. To avoid static
sparking and injury from splashing, always flush at
the lowest possible pressure.
There are times when you only want to purge the
remote mix manifold and the spray device, such as:
• end of potlife
• breaks in spraying that exceed the potlife
• overnight shutdown or end of shift
• before servicing the remote mix manifold, hose or
gun.
1. Command the Mix Unit to Standby.
2. If you are using a high pressure spray device or
an electrostatic gun, shut off the atomizing air.
3.
To reduce the risk fire and explosion, shut off
electrostatics before flushing the gun.
If using an electrostatic gun, shut off the
electrostatics before flushing the gun.
4. Command the Mix Unit to Purge A,
Purge B, or Recipe Purge. (See
Purge Mode Sequence, page
spray device into a grounded metal pail until
the purge sequence is complete. When done
purging, the Mix Unit automatically switches to
Standby mode, signalling the spray device to
stop spraying.
5. If the Mix Unit is not completely clean, repeat
Step 5.
NOTE: For optimal efficiency, adjust purge
NOTE:
NOTE:
sequence times so only one cycle is required.
NOTE:
NOTE: The remote mix manifold and gun remain full
NOTE:
of solvent after purging.
3A4486D
42.) Trigger the
Operation Using Advanced Display Module (ADM)
Flush
Flush the
Flush
the System
the
System
System
To avoid fire and explosion, always ground
equipment and waste container. To avoid static
sparking and injury from splashing, always flush at
the lowest possible pressure.
Follow this procedure before:
• the first time material is loaded into the equipment
• servicing
• shutting down equipment for an extended period
of time
• putting equipment into storage
Single
Single Color
Single
Color System
Color
System
System
1. Relieve the pressure.
Pressure Relief Procedure, page
2. Disconnect the color and catalyst supply lines
from the pump inlet manifolds, and connect
regulated solvent supply lines.
3. Set the solvent supply pressure regulator at the
lowest pressure possible. Generally a setting
of 25–50 psi (0.18–0.35 MPa, 1.8–3.5 bar) is
sufficient.
4. Enable manual override on
System Screen 1, page
5. On the ADM, go to the Fill screen for Mix Unit
#1. Set the Material to Color (A). Press
The system will pump solvent through pump A
all the way to the gun.
6. Hold a metal part of the spray device firmly to a
grounded metal pail. Trigger the spray device
until clean solvent dispenses.
7. On the ADM, go to the Fill screen for Mix Unit
#1. Set the Material to Catalyst (B). Press
The system will pump solvent through pump B
all the way to the gun.
8. Relieve the pressure.
Pressure Relief Procedure, page 19
9. Repeat for Mix Unit #2.
See
19.
68.
.
See
21
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents