Operation Using a Programmable Logic Controller (PLC)
Operation Flow
Flow Charts
Operation
Operation
Flow
NOTE:
NOTE: All flow charts reference registers for Mix Unit
NOTE:
#1. For Mix Unit #2, reference the Network Maps for
corresponding register indices.
Purge Mode
Mode Sequence
Sequence
Purge
Purge
Mode
Sequence
System opens color solvent valve at remote stack to allow
solvent flow through mix manifold and out gun.
Purge time set according to the flush sequence assigned to
System Mode = Standby: Mix Not Ready
System closes color solvent valve at remote stack.
42
Charts
Charts
Purge A System Command
Write '6' to Input Re gis te r 00
Is Mix Unit #1 in Standby or
Pumps Of f?
System Mode = Purge A
(Output Register 00 = '9')
material A in re cipe .
Is solvent flow switch 1 ON?
Purge time expired?
(Output Register 00 = '13')
NOTE: Purge B command works
similarly with the catalyst lines and
solvent flow switch 2.
No action taken.
Either pumps are currently
running or an alarm condition
exists.
NO
Purge no flow timeout expired?
No solvent flow detected.
Generate alarm.