Graco ProMix PD2K Operation page 40

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Operation Using a Programmable Logic Controller (PLC)
Network
Network
Network
Modbus
Modbus
Modbus
Input
Input
Input ID ID ID
Register
Register
Register
0010
42100
0011
42102
0012
42104
0013
42106
0014
42108
0015
42110
0016
42112
0017
42114
0018
42116
0019
42118
0020
43100
0021
43102
0022
43104
0023
43106
0024
43108
0025
43110
40
Parameter
Parameter Name
Parameter
Name
Name
System Mode Command
Clear Active Alarm/Deviation
Goto Recipe Number
Mix Control Set Point
Mix Fill Set Point
Pump Flush Sequence #/Prime
Material #
Flush/Prime Pump Command
Job Complete
Gun 2 Trigger
Fluid Control Mode
Command Argument 1
Command Argument 2
Command Argument 3
Command Argument 4
Command Argument 5
Command Argument 6
Data
Data
Data
Units
Units
Units
Type
Type
Type
uint32
NONE
uint32
NONE
uint32
NONE
uint32
cc/min or
PSI
unit32
cc/min or
PSI
unit32
NONE
unit32
NONE
unit32
NONE
unit32
NONE
unit32
NONE
unit32
NONE
unit32
NONE
unit32
NONE
unit32
NONE
unit32
NONE
unit32
NONE
Range
Range
Range
0 = No OP
1 = Power Pumps
2 = Remote Stop
3 = Color Change
4 = Mix Fill
5 = Mix
6 = Purge A
7 = Purge B
8 = Standby
9 = Recipe Purge
1 = Clear Active Alm/Dev
0, 1 – 30
1 - 1600
1 – 1600
1 –5, 1 – 40
0 = No OP
1 = Flush Pump 1
2 = Prime Pump 1
3 = Flush Pump 2
4 = Prime Pump 2
5 = Flush Pump 3
6 = Prime Pump 3
7 = Flush Pump 4
8 = Prime Pump 4
9 = Fill Line
10 = Flush Line
11 = Stop Line Fill/Flush
1 = Trigger job complete
0 = Gun not triggered
1 = Gun triggered
0 = Flow Control
1 = Pressure Control
N/A
N/A
N/A
N/A
N/A
N/A
3A4486D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents