Graco ProMix PD2K Operation page 37

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

INPUT REGISTER
REGISTER 06
INPUT
INPUT
REGISTER
The Flush/Prime Pump Command register is used in
conjunction with the Pump Flush Sequence/Prime
Material Selection register (see INPUT REGISTER
05 and 15) to independently prime or flush an inactive
pump. The desired pump MUST be in Standby
mode. Confirm by reading the corresponding Pump
Status output register (see OUTPUT REGISTERS
06, 07, 32, and 33).
If an invalid Flush Sequence or invalid material
number is written to the Pump Flush Sequence/Prime
Input
Input
Input Value
Value
Value
Operation Mode
Operation
Operation
0
No OP
1
Flush Pump 1
2
Prime Pump 1
3
Flush Pump 2
4
Prime Pump 2
5
Flush Pump 3
6
Prime Pump 3
7
Flush Pump 4
8
Prime Pump 4
9
Fill Line
10
Flush Line
11
Stop Line Fill/Flush
INPUT REGISTER
REGISTER 07
INPUT
INPUT
REGISTER
The Job Complete register is used to log the current
job remotely. Write a '1' to the register to command
the ProMix PD2K to flag a job complete.
(See
Usage Screen, page 66
Job Logs and Job Complete.)
NOTE:
NOTE: This register is not polled by the ProMix
NOTE:
PD2K. A job is logged only when a value of '1'
3A4486D
06 and
and 16:
16: Flush/Prime
Flush/Prime Pump
06
and
16:
Flush/Prime
Mode
Mode
Description
Description
Description
The system takes no action.
Flush Pump 1 using selected sequence.
Prime Pump 1 using selected material.
Flush Pump 2 using selected sequence.
Prime Pump 2 using selected material.
Flush Pump 3 using selected sequence.
Prime Pump 3 using selected material.
Flush Pump 4 using selected sequence.
Prime Pump 4 using selected material.
Run selected material from the pump and out the gun.
Run solvent through hoses for selected material from the pump and
out the gun.
Stop Line Fill/Flush command.
07 and
and 17:
17: Job
Job Complete
Complete
07
and
17:
Job
Complete
for more information on
Operation Using a Programmable Logic Controller (PLC)
Pump Command
Command
Pump
Command
Material Selection register then the Flush/Prime
command will be ignored. The user must know
what material is assigned to each pump. (See
Color Change Kits Instruction Manual 332455 for
color/catalyst pump mapping.)
This register can also be used to fill or flush a specific
material hose.
is written to this register. It is recommended the
automation reset this register by writing a '0' to it at
all other times to avoid inadvertently logging a job.*
* * * It is recommended to wait at least 500 msec for the
PD2K to process before resetting to '0'.
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents