Graco ProMix PD2K Operation page 45

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Line Fill
Fill and
and Flush
Flush Sequences
Line
Line
Fill
and
Flush
Write Material #
(1 - 40) to Input Register 05
Write Line Flush Command
'10' to Input Register 06
Is Current System Mode =
Standby ?
(Output Register 00 = 1 1,
12, 13)
Is corresponding pump
primed with solvent?
YES
Pump begins to run solvent out
the pump, through selected hose,
and out the gun.
Current System Status =
Filling/Flushing
(Output Register 00 = '15')
3A4486D
Sequences
Sequences
NO
NO
Line
NO
Operation Using a Programmable Logic Controller (PLC)
NOTE: System must be in
Standby to flush or fill a hos e
line since it will run ma te ria l
from the pump all th e wa y
out the gun.
No action taken.
No action taken.
NOTE: The pump mu s t be
primed with the app ropria te
material before comma nding
to fill or flush a hos e line .
No action taken.
Write Stop Line Fill/Flush
(Write '11' to Input Re gis te r 06)
YES
Current System Mode is set to
Standby: Mix Not Ready
(Output Register 00 = '13')
Write Material #
(1 - 40) to Input Register 05
Write Line Fill Command
'9' to Input Register 06
Is Current System Mode =
Standby ?
NO
(Output Register 00 = 1 1,
Is corresponding pump
NO
primed with selected material?
Pump begins to run material out
the pump, through selected hose,
and out the gun.
Current System Status =
Filling/Flushing
(Output Register 00 = '15')
?
.
12, 13)
YES
YES
Line
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents