Operation Using a Programmable Logic Controller (PLC)
OUTPUT REGISTER
OUTPUT
OUTPUT
REGISTER 01
REGISTER
The Event Flag register provides indication when an
event (Alarm or Deviation) has occurred that requires
user acknowledgement.
• The value will be 0 if there are no events requiring
acknowledgement.
• The value will be 1 if there is at least one event
needing acknowledgement.
OUTPUT
OUTPUT REGISTER
OUTPUT
REGISTER 02
REGISTER
Flow/Pressure
Flow/Pressure
Flow/Pressure
The Actual Mix Flow/Pressure register reports back
the instantaneous mixing flow rate in cc/min or mixing
pressure in PSI. This register is primarily used to
reflect that the Mix Unit is on it's target fluid control
set point. See
INPUT REGISTER 03 and 13: Mix
Control Set Point, page 36
NOTE: This register is valid only during a mix
NOTE:
NOTE:
operation.
OUTPUT REGISTER
REGISTER 03
OUTPUT
OUTPUT
REGISTER
Ratio
Ratio
Ratio
The Actual Mix Ratio register contains the
instantaneous calculated mix ratio.
• The value reported is the ratio antecedent
multiplied by 100. The ratio consequent is
always 1.
Example
: Value = 250 >> A mix ratio of 2.5:1
(Material A to Material B)
• If the current recipe ratio is 0:1 (1K recipe) this
value will be 0.
This register is valid only during a mix operation.
OUTPUT
OUTPUT REGISTER
OUTPUT
REGISTER 04
REGISTER
Potlife Remaining
Remaining
Potlife
Potlife
Remaining
The Actual Potlife Remaining register contains
the current amount of time remaining in the active
recipe's potlife in seconds.
NOTE: If potlife is disabled for the active recipe or at
NOTE:
NOTE:
initial startup this value will be 0xFFFFFFFF.
OUTPUT REGISTER
REGISTER 05:
OUTPUT
OUTPUT
REGISTER
Input
Input Status
Input
Status
Status
OUTPUT REGISTER
REGISTER 31:
OUTPUT
OUTPUT
REGISTER
Input Status
Status
Input
Input
Status
The Gun Trigger Input Status registers contain the
status of the Gun Trigger Discrete Inputs.
• The value is 0 if the input is OPEN (gun not
triggered).
• The value is 1 if the input is CLOSED (gun
triggered).
28
01 and
01
and 27:
and
27: Event
27:
Event Flag
Event
Flag
Flag
02
02 and
and 28:
and
28: Actual
28:
Actual
Actual Mix
Mix
Mix
.
03 and
and 29:
29: Actual
Actual Mix
Mix
03
and
29:
Actual
Mix
04 and
04
and 30:
and
30: Actual
30:
Actual
Actual Mix
Mix
Mix
05: Gun
Gun 1 1 1 Trigger
Trigger
05:
Gun
Trigger
31: Gun
Gun 2 2 2 Trigger
Trigger
31:
Gun
Trigger
This data register is valid only for systems configured
to use the discrete inputs for the Gun Triggers.
Gun Trigger Signal, page 71
OUTPUT REGISTERS
OUTPUT
OUTPUT
REGISTERS 06:
REGISTERS
OUTPUT REGISTERS
REGISTERS 07:
OUTPUT
OUTPUT
REGISTERS
OUTPUT REGISTERS
REGISTERS 32:
OUTPUT
OUTPUT
REGISTERS
OUTPUT REGISTERS
OUTPUT
OUTPUT
REGISTERS 33:
REGISTERS
The Pump Status registers contain a number that
indicates the state of Pumps 1 – 4. This status can be
used for general monitoring of the pump state, or as
an indicator for driving independent pump operations.
See
INPUT REGISTER 06 and 16: Flush/Prime
Pump Command, page
Table 4 4 4 Pump
Table
Table
Pump States
Pump
States for
States
for Output
for
32, and
and 33
33
32,
32,
and
33
Number
Number
Number
Pump
Pump State
Pump
State
State
0
Off
1
Standby
2
Busy
3
Flushing
4
Priming
OUTPUT
OUTPUT REGISTER
OUTPUT
REGISTER 08:
REGISTER
OUTPUT REGISTER
REGISTER 09:
OUTPUT
OUTPUT
REGISTER
OUTPUT REGISTER
REGISTER 34:
OUTPUT
OUTPUT
REGISTER
OUTPUT REGISTER
OUTPUT
OUTPUT
REGISTER 35:
REGISTER
The Pump Material register values indicate what
material is currently loaded in each pump.
• Colors are numbered 1 – 32.
• Catalysts are numbered 33 – 40.
• The value is 0 if the pump is filled with solvent.
• The value is 61 if the material is unknown, such as
initial startup.
.
06:
06: Pump
Pump 1 1 1 Status
Pump
Status
Status
07: Pump
Pump 2 2 2 Status
Status
07:
Pump
Status
32: Pump
Pump 3 3 3 Status
Status
32:
Pump
Status
33: Pump
33:
Pump 4 4 4 Status
Pump
Status
Status
37.
Output Registers
Output
Registers 06,
Registers
06, 07,
06,
07,
Description
Description
Description
The pump is powered
down or not enabled.
The pump is powered
but not currently
active.
The pump is currently
in a recipe change or
mixing operation.
The pump is currently
flushing with solvent
The pump is currently
priming with material.
08:
08: Pump
Pump 1 1 1 Material
Pump
Material
Material
09: Pump
Pump 2 2 2 Material
Material
09:
Pump
Material
34: Pump
Pump 3 3 3 Material
Material
34:
Pump
Material
35:
35: Pump
Pump 4 4 4 Material
Pump
Material
Material
3A4486D
See
07,

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents