Graco ProMix PD2K Operation page 82

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Setup Mode Screens
Custom Valve
Valve Mapping
Mapping
Custom
Custom
Valve
Mapping
For a PD2K system that has color change, the user
has an option for how the control solenoids are
mapped on the control modules. Selecting Standard
(default) will use the traditional, static valve mapping.
The static maps are laid out logically and established
for retro-fitting. If Standard is selected no additional
set up for the color change valves is required at the
ADM. For more information or to see the static map
layouts, refer to manuals 332455 and 333282.
By selecting Custom, every color change solenoid
may be assigned to any unique, valid control module
location. This option offers the ultimate customization
as well as the benefit of consolidation of equipment.
Additionally, custom valve mapping enables some
advanced color change valve features.
NOTE: This option applies to all pumps, so changing
NOTE:
NOTE:
it for one will change it for all.
NOTE: When going from Standard to Custom,
NOTE:
NOTE:
the PD2K will automatically pull in the static map
assignments for all valves as a starting point. When
going from Custom to Standard, the PD2K will clear
all custom valve assignments and revert to the static
mappings.
Pump
Pump Screen
Pump
Screen - - - Advanced
Screen
Advanced Configuration
Advanced
Figure 55 Pump Screen, Advanced Configuration
Inlet Color
Color Change
Change
Inlet
Inlet
Color
Change
Select Multiple if each individual material has its own
valve on the inlet color stack for a particular pump.
82
Configuration
Configuration
Select Single if there is more than one material using
a single valve on the inlet color stack (i.e., a piggable
system). This option is only available for pumps that
have more than one color change material.
NOTE: For systems that select Single, it is expected
NOTE:
NOTE:
the user knows when a particular material is plumbed
and filled to the inlet stack before performing a color
change. The PD2K system does not know what
material is connected up stream of the inlet valve
stack.
Pump Air
Pump
Pump
Air Purge
Air
Purge
Purge
Select Enable to add an air purge valve to the pump
inlet stack to allow for an air/solvent chop flush of the
pump out the dump valve. Select Disable if no air
purge valve will be used for the pump. This option is
only available for color pumps. See Pump Air/Solvent
Chop on
Pump Screen - Valve Assignment, page
for further detail.
Outlet
Outlet Color
Outlet
Color Change
Color
Change
Change
Select Multiple if each individual material has its own
valve on the outlet color stack for a particular pump.
Select Single if there is more than one material using
a single hose connected to the outlet color stack.
This option is only available for pumps that have
more than one color change material.
NOTE: If Single is selected, the hose connected
NOTE:
NOTE:
to the outlet stack will need to be purged before
completing a color change.
Remote Color
Color Change
Change
Remote
Remote
Color
Change
Select Multiple if each individual material has its own
valve on the remote color stack for a particular pump.
Select Single if there is more than one material
using a single hose connected to the remote color
stack. Select Disable if there are no remote color
change valves (only solvent and air) for the pump.
The Disable option is only available if Mix-at-Wall is
enabled, and Single is only available for pumps that
have more than one color change material.
NOTE: Unless Disabled is selected, this must match
NOTE:
NOTE:
the selection for Outlet Color Change unless.
NOTE: If Single is selected, the hose connected
NOTE:
NOTE:
between the outlet stack and remote stack will need
to be purged before completing a color change.
84,
3A4486D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents