Operation Using a Programmable Logic Controller (PLC)
Network
Modbus
Network
Network
Modbus
Modbus
Output
Output
Output ID ID ID
Register
Register
Register
0010
41020
0011
41022
0012
41024
0013
41026
0014
41028
0015
41030
0016
41032
0017
41034
0018
41036
0019
41038
0020
41040
0021
41042
0022
41044
0023
41046
0024
41048
0025
41050
0026
42000
32
Parameter Name
Name
Parameter
Parameter
Name
Actual Pump 1 Flow
Rate
Actual Pump 2 Flow
Rate
Actual Pump 1 Fluid
Pressure
Actual Pump 2 Fluid
Pressure
Active Recipe Number
Active Recipe Material
A
Active Recipe Material
B
Active Recipe Material
A Flush Sequence
Active Recipe Material
B Flush Sequence
Active Recipe Ratio
Set Point
Active Recipe Potlife
Time Set Point
Job Number
Job A Sprayed Volume
Job B Sprayed Volume
Job Solvent Volume
Safety Interlock Input
Status
Current System Mode
Data Type
Type
Units
Data
Data
Type
Units
Units
uint32
cc/min
uint32
cc/min
uint32
PSI
uint32
PSI
uint32
NONE
uint32
NONE
uint32
NONE
uint32
NONE
uint32
NONE
uint32
NONE
uint32
min
uint32
NONE
cc
unit32
cc
unit32
cc
unit32
unit32
NONE
uint32
NONE
Range
Range
Range
0 – 800
0 – 800
0 – 1500
0 – 1500
0 – 30, 61
1 – 32, 61
33 – 40, 61
1 – 5
1 – 5
0 – 5000
0 – 999
0 – 9999
0 – 999999999
0 – 999999999
0 – 999999999
0 = Open
1 = Closed
1 = Pump Off
2 = Color Change
3 = Color Change: Purge A
4 = Color Change: Purge B
5 = Color Change: Fill
6 = Mix Fill
7 = Mix
8 = Mix Idle
9 = Purge A
10 = Purge B
11 = Standby: Mix Ready
12 = Standby: Fill Ready
13 = Standby: Mix Not Ready
14 = Standby: Alarm
15 = Line Filling/Flushing
16 = Pump Prime/Flush
17 = Maintenance/Calibration