Operation Using a Programmable Logic Controller (PLC)
INPUT REGISTER
REGISTER 02
INPUT
INPUT
REGISTER
Recipe Number
Number
Recipe
Recipe
Number
The Go to Recipe Number register is used as a
queue for the next recipe to be loaded when a recipe
change is initiated. A number between 0 and 30 can
be written to this register. However, a recipe must be
enabled via the ADM before it can be loaded. See
Recipe Screen, page
76.
NOTE:
NOTE:
NOTE: Writing to this register does not trigger a recipe
change.
See
Color Change Sequence, page
INPUT
INPUT
INPUT REGISTER
REGISTER 03
REGISTER
Set Point
Point
Set
Set
Point
The Mix Control Set Point register is used to set and
adjust the mixing fluid control set point. It can be
changed at any time, and the system will immediately
adjust to the new set point.
• If the Mix Unit is configured for Flow Control this
value can be set between 5 and 1600 cc/min for a
2K recipe, and between 5 and 800 for a 1K recipe.
See Fluid Control on
• If the Mix Unit is configured for Pressure Control
this value can be set between 0 and the maximum
pump pressure in PSI. See Fluid Control on
System Screen 4, page
NOTE:
NOTE:
NOTE: The Flow Control must be configured to
'Network' via System Screen 4 on the ADM. If set
to 'Discrete' this register is ignored and set point
adjustment is handled via the discrete input. See
Analog Inputs, page
24.
36
02 and
and 12:
12: Go
Go To
To
02
and
12:
Go
To
46.
03
03 and
and 13:
and
13:
13: Mix
Mix
Mix Control
Control
Control
System Screen 4, page
71.
INPUT REGISTER
INPUT
INPUT
Point
Point
Point
The Mix Fill Set Point register is used to set an
alternate control set point during the mix fill process
(see Mix Fill Set Point on
• If the Mix Unit is configured for Flow Control this
value can be set between 5 and 1600 cc/min for a
2K recipe, and between 5 and 800 for a 1K recipe.
See Fluid Control on
• If the Mix Unit is configured for Pressure Control
this value can be set between 1 and the maximum
pump pressure in PSI. See Fluid Control on
System Screen 4, page
NOTE: The Flow Control must be configured
NOTE:
NOTE:
to 'Network' via System Screen 4 on the ADM.
If set to 'Discrete' this register is ignored and
set point is handled via the discrete input. See
Analog Inputs, page
INPUT
INPUT REGISTER
INPUT
Sequence/Prime
Sequence/Prime Material
Sequence/Prime
71.
The Pump Flush Sequence/Prime Material Selection
register is used in conjunction with the Flush/Prime
Pump Command register (see
and 16: Flush/Prime Pump Command, page 37
independently prime or flush an inactive pump.
• Write a value between 1 and 5 if flushing a pump.
• Write a value between 1 and 32 if priming a Color
pump.
• Write a value between 33 and 40 if priming a
Catalyst pump.
NOTE:
NOTE: It is important that the user know which
NOTE:
material is assigned to each pump. An invalid
selection will be ignored by the ProMix PD2K.
REGISTER 04
04 and
and 14:
REGISTER
04
and
System Screen 2, page
System Screen 4, page
71.
24.
REGISTER
REGISTER 05
05
05 and
and 15:
and
Material Selection
Material
Selection
Selection
INPUT REGISTER 06
14: Mix
Mix Fill
Fill Set
Set
14:
Mix
Fill
Set
69).
71.
15:
15: Pump
Pump
Pump Flush
Flush
Flush
) to
3A4486D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents