Graco ProMix PD2K Operation page 106

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

System Errors
Code
Type
Description
Code
Code
Type
Type
Description
Description
QAD#
Alarm
Differential
Pressure A
Over B
QBD#
Alarm
Differential
Pressure B
Over A
System Errors
System
System
Errors
Errors
Code
Code
Code
Type
Type
Type
Description
Description
Description
EB00
Rec-
Stop Button
ord
Pressed
EBC#
Rec-
PLC Power
ord
Command
for Mix Unit #
EBI#
Rec-
Power Button
ord
Pressed Mix
Unit #
EC00
Rec-
Setup
ord
Value(s)
Changed
EL00
Rec-
System
ord
Power On
EM00
Rec-
System
ord
Power Off
EMI#
Advi-
Pump Off Mix
sory
Unit #
Advi-
Factory
ES00
sory
Defaults
106
Problem
Problem
Problem
Mix Unit # low differential
pressure. This alarm is
active only during Mix
mode.
Mix Unit # high differential
pressure. This alarm is
active only during Mix
mode.
Problem
Problem
Problem
Record of a stop button
press.
Record of pumps
powered off by PLC
command.
Record of pumps
powered off by button
press.
Record of changing
setup variables.
Record of power cycle
(ON).
Record of power cycle
(OFF).
The pumps are not
powered and are unable
to move for Mix Unit #.
Record of defaults being
loaded.
Cause
Cause
Cause
There is a leak on the B
side.
The B side pump is
cavitating.
There is a leak on the A
side.
The A side pump is
cavitating.
Cause
Cause
Cause
Indicates system stop
key on ADM was
pressed.
The PLC command was
used to shut down pump
power.
The power button on the
ADM was used to shut
down pump power.
Indicates date and time
when setup values were
changed.
Indicates date and
time when system was
started.
Indicates date and time
when system was turned
off.
Pump power was turned
off or an error occurred.
Solution
Solution
Solution
Check the system for
internal and external
leaks on all catalyst
manifolds and plumbing.
Check paint supply on
the B side, increase paint
supply pressure.
Check the system for
internal and external
leaks on all color
manifolds and plumbing.
Check paint supply on
the A side, increase paint
supply pressure.
Solution
Solution
Solution
n/a
No action required.
No action required.
n/a
n/a
n/a
Start pumps by pressing
pump start key on
Advanced Display
module.
n/a
3A4486D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents