Shutdown - Graco ProMix PD2K Operation

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Operation Using Advanced Display Module (ADM)
Color Change
Change System
System
Color
Color
Change
System
1. Relieve the pressure.
Pressure Relief Procedure, page
2. Attach regulated solvent supply lines as follows:
• Multiple
Multiple color/single
Multiple
color/single
color/single catalyst
color side, do not disconnect the color supply
line from the inlet manifold of Pump A. Instead,
connect a regulated solvent supply line to the
designated solvent valve on the color valve
manifold. On the catalyst side, disconnect
the catalyst supply line from the inlet manifold
of Pump B, and connect a regulated solvent
supply line.
Multiple color/multiple
color/multiple catalyst
• Multiple
Multiple
color/multiple
Connect regulated solvent supply lines to
the designated solvent valves on the color
and catalyst valve manifolds. Do not connect
solvent supply lines directly to the inlet
manifolds of the pumps.
3. Set the solvent supply pressure regulator at the
lowest pressure possible. Generally a setting
of 25–50 psi (0.18–0.35 MPa, 1.8–3.5 bar) is
sufficient.
4. On the ADM, go to the Fill screen for Mix Unit
#1. Select Color (A). Enter the color number in
the box to the right.
5. Select the Flush Line box.
6. If the solvent is not already loaded, press the
Prime softkey
solvent into the selected pump and out the outlet
dump valve.
7. Press the Fill softkey
flush the selected Color (A) line with the solvent
until the user presses Stop
22
See
19.
catalyst system:
catalyst
system: On the
system:
catalyst system:
system:
catalyst
system:
. The Mix Unit will prime
. The Mix Unit will
.
8. Hold a metal part of the gun firmly to a grounded
metal pail. Trigger the gun until clean solvent
dispenses.
9. Repeat for each color line.
10. Relieve the pressure.
Pressure Relief Procedure, page 19
11. Repeat for Mix Unit #2.

Shutdown

Shutdown
Shutdown
1. Flush out the mixed material to avoid potlife errors
and fluid setup in the lines. See
2. Follow the
Pressure Relief Procedure, page
3. Close the main air shutoff valve on the air supply
line and on the control box.
4. Press
on the Display Module to turn off
power to the pumps to display the following
pop-up screen. Make sure that the system is in
Standby mode.
5. Select either Mix Unit, or both, to power off.
6. Shut off system power (0 position).
See
Purging, page
21.
19.
3A4486D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents