Graco ProMix PD2K Operation page 33

Dual fluid panel, electric proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Network
Network
Network
Modbus
Modbus
Modbus
Output
Output
Output ID ID ID
Register
Register
Register
0027
42002
0028
42004
0029
42006
0030
42008
0031
42010
0032
42012
0033
42014
0034
42016
0035
42018
0036
42020
0037
42022
0038
42024
0039
42026
0040
42028
0041
42030
0042
42032
0043
42034
0044
42036
0045
42038
0046
42040
0047
42042
0048
42044
0049
42046
3A4486D
Operation Using a Programmable Logic Controller (PLC)
Parameter
Parameter
Parameter Name
Name
Name
Event Flag
Actual Mix
Flow/Pressure
Actual Mix Ratio
Actual Mix Potlife
Remaining
Gun 2 Trigger Status
Pump 3 Status
Pump 4 Status
Pump 3 Material
Pump 4 Material
Actual Pump 3 Flow
Rate
Actual Pump 4 Flow
Rate
Actual Pump 3Fluid
Pressure
Actual Pump 4 Fluid
Pressure
Active Recipe Number
Active Recipe Material
A
Active Recipe Material
B
Active Recipe Material
A Flush Sequence
Active Recipe Material
B Flush Sequence
Active Recipe Ratio
Set Point
Active Recipe Potlife
Time Set Point
Job Number
Job A Sprayed Volumn
Job B Sprayed Volume
Data Type
Data
Data
Type
Type
Units
Units
Units
uint32
NONE
uint32
cc/min
or PSI
uint32
NONE
sec
uint32
uint32
NONE
uint32
NONE
uint32
NONE
uint32
NONE
uint32
NONE
uint32
cc/min
uint32
cc/min
uint32
PSI
uint32
PSI
uint32
NONE
uint32
NONE
uint32
NONE
uint32
NONE
uint32
NONE
uint32
NONE
uint32
min
uint32
NONE
cc
unit32
cc
unit32
Range
Range
Range
0 = No Events
1 = New Event
1 – 1600
0 – 5000
0 – 59940
0 = Gun not triggered
1 = Gun triggered
0 = Off
1 = Standby
2 = Busy
3 = Flushing
4 = Priming
0 = Off
1 = Standby
2 = Busy
3 = Flushing
4 = Priming
0 – 40, 61
0 – 40, 61
0 – 800
0 – 800
0 – 1500
0 – 1500
0 – 30, 61
1 – 32, 61
33 – 40, 61
1 – 5
1 – 5
0 – 5000
0 – 999
0 – 9999
0 – 999999999
0 – 999999999
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Promix pdPromix pd1kAc1002Ac3002Ac2002Ac4002

Table of Contents