Setup Mode Screens
Pump Screen
Screen 2 2 2
Pump
Pump
Screen
Pump screen 2 sets the pressure transducer settings
for the pump.
Figure 63 Pump Screen 2, Default Settings Enabled
Figure 64 Pump Screen 2, Default Settings Disabled
86
Default Settings
Default
Default
Settings
Settings Selected
Selected
Selected
When the "Use Default Settings" box is selected,
default settings are used for the calibration values,
and the fields are grayed out.
Default Settings
Default
Default
Settings
Settings Not
Not Selected
Not
When the "Use Default Settings" box is not selected,
the following calibration values must be entered.
Invalid values will be over-ridden and the system will
automatically select the default settings.
• Inlet Offset Factor: This field is only used if Inlet
Pressure
Pressure in
Pressure
Pump Screen 1, page 81
Monitor; it is grayed out if set to Disabled. The
valid range is -01.20 to +01.20 mV/V.
• Inlet Sensitivity Factor: This field is only used if
Inlet Pressure
Pressure in
Inlet
Inlet
Pressure
Pump Screen 1, page 81
to Monitor; it is grayed out if set to Disabled. The
valid range is 18.80 to 21.20 mV/V.
• Outlet Offset Factor: The valid range is -01.20 to
+01.20 mV/V.
• Outlet Sensitivity Factor: The valid range is 18.80
to 21.20 mV/V.