(3)
Remove the platen switch actuator by press-
ing and turning it in the direction of the arrow
(arrows 1 to 3 ). Then remove the connec-
tor and 2 claws.
7.7.12
Carriage 1
(1)
Remove the original glass, the left top cover,
the transparent indicator cover, the upper rear
cover and the upper exit cover.
(2)
Remove the cable guide (1 screw).
(3)
Remove the 2 brackets which attach carriage
1 to the wire (1 screw each).
4560/4570 OPTICAL
Platen switch actuator
Platen
Platen switch
switch
claws
Wire fixing bracket
7 - 24
Home switch
claws
Cable guide