18.7 About Original Jams and ADF Errors
18.7.1
Type of jam
(1) Feed unit jam
(2) Transport jam
(3) Exit jam
(4) Two-original(2in1)jam in
18.7.2
Jam timer
Category
Feed unit
Until aligning sensor turns ON after of pre-feeding
Until aligning sensor turns ON after start of pre-feeding
of 1st original in 2in1 feed
Until aligning sensor turns ON after start of pre-feeding
of 2nd original in 2in1 feed
Until aligning sensor turns OFF from start of transport by
aligning roller after aligning during dual-side feed
Until aligning sensor turns OFF from start of transport by
aligning roller after aligning 1st original in 2in1 feed
Until aligning sensor turns OFF from start of original feed
after joining 2nd original has ended in 2in1 feed
Transport section
Until the exit sensor (exit inversion sensor) turns ON after
start of discharge
Until the exit sensor (exit inversion sensor) turns ON after
start of dual-side inversion
Until the exit sensor (exit inversion sensor) turns ON after
start of dual-side discharge
Until the exit sensor (exit inversion sensor) turns ON after
start of dual-side original feed
Exit section
Until the exit sensor (exit inversion sensor) turns OFF after
exit sensor (exit inversion sensor) turns ON during
discharge
Until original feed ends after start of motor reverse drive in
the dual-side mode
4560/4570 RADF
: Original has not arrived at aligning sensor during pre-feeding
Original has not arrived during feed of 1st original in 2in1 feed
Original is retained at aligning sensor during feed in regular mode
: Original has not arrived at the exit sensor(exit inversion sensor)during
discharge
Original has not arrived at the exit sensor(exit inversion sensor)during
dual-side feed
: Original is retained at the exit sensor(exit inversion sensor)during dis-
charge
Original is retained at the exit sensor(exit inversion sensor)during dual-
side feed
: Original has not arrived at aligning sensor during feed of 2nd original
in feed unit 2in1 feed
Function
18 - 26
Pulse Value Timer Value(sec)
1318
0.96
1318
0.96
1318
0.96
2620
1.12
2620
1.12
2433
1.1
(Note 1)
3437
1.35
3067
1.3
3067
1.3
3437
2.1
2699
1.1
2215
(Note 2)