Ess Nvram Data Compare Fail - Xerox VersaLink B7025 Service Manual

Hide thumbs Also See for VersaLink B7025:
Table of Contents

Advertisement

116-334 ESS NVRAM Data Compare Fail

116-334 ESS NVRAM data compare fail.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Enter
dC125
Faults. If another 124-3XX fault code is displayed, perform the relevant
RAP.
3.
Ensure that all connectors on the drive PWB,
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
4.
Reload the software,
GP
4.
5.
Perform the
OF2
Special Boot Modes RAP.
Status Indicator RAPs
116-334, 116-340
WARNING
GP
10.
PL 1.10 Item 3
and the ESS PWB,
116-340 Not Enough Memory RAP
116-340 Insufficient memory was detected during initialization. A PS option requiring an addi-
tional memory was installed but memory was not added.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Switch off, then switch on the machine,
PL 3.10
April 2017
2-508
WARNING
GP
10. Disconnect the power cord. Electricity can cause
GP
10.
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
Launch Issue