013-210, 013-211 Booklet Staple Move Home Sensor Fail
RAP
BSD-ON:
BSD 13.16 Office Finisher LX Booklet Staple Positioning
013-210 Booklet staple move home sensor does not actuate within designated time period.
013-211 Booklet staple move home sensor does not deactuate within designated time period.
Initial Actions
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Ensure the staple head is free from obstructions.
Check
dC122
Fault History for 013-306 or 013-307 faults. If either fault is listed, first per-
form the relevant procedure:
013-306
Booklet Safety Switches Open RAP.
013-307
Booklet Cover Open RAP.
Procedure
Enter
dC330
code 013-143. Move the booklet staplers to actuate the booklet staple move
home sensor,
PL 13.55 Item
13. The display changes.
Y
N
Check the wiring between
J8897
pin 2 and
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
P/J8991
approximately +5VDC.
Y
N
Install a new booklet PWB,
PL 13.70 Item
Measure the voltage between
P/J8991
booklet staplers to actuate the booklet staple move home sensor. The voltage changes.
Y
N
Install a new booklet staple move home sensor,
Install a new booklet PWB,
PL 13.70 Item
Enter
dC330
code 013-028 and 013-029 alternately. The stapler move motor runs.
Y
N
Check the wiring between
P/J8992
pins 1 to 6 on the booklet PWB and
booklet stapler move motor for an open or short circuit, or loose or damaged connectors.
The wiring is good.
Y
N
Reconnect or repair as necessary.
A
B
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
P/J8991
pin 2 for an open or short circuit, or
pins 3 and 1 on the booklet PWB. The voltage is
4.
pin 2 on the booklet PWB and ground. Move the
PL 13.55 Item
13.
4.
P/J8906
A
B
Monitor the voltage at J8984, pin 3. Enter
An AC clock pulse is detected.
Y
N
Check the wiring between
a new finisher PWB,
Install a new booklet stapler move motor,
new booklet PWB,
PL 13.70 Item
Check the wiring for an intermittent fault.
on the
April 2017
2-99
dC330
code 013-028 and 013-029 alternately.
J8984
pin 3 and
J8985
pin 4. If the wiring is good, install
PL 13.45 Item
2.
PL 13.55 Item
9. If the fault persists, install a
4.
Status Indicator RAPs