116-355, 363, 367, 370, 373, 376 Fatal Error RAP
116-355 Fatal error related to the SNMP Agent.
116-363 BMLinkS/print service software failure.
116-367 Overall fatal error of Parallel.
116-370 Fatal error of XJCL.
116-373 Fatal error related to dynamic DNS.
116-376 Port 9100 software fail.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Advise the customer to check that the TCP/IP ports are correctly configured.
2.
Switch off, then switch on the machine,
3.
Ensure that all connectors on the drive PWB,
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
4.
Reload the software,
GP
4.
5.
Perform the
016A
Scan to Network Error Entry RAP.
6.
Perform the
OF2
Special Boot Modes RAP.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10.
PL 1.10 Item 3
and the ESS PWB,
116-364, 365, 366, 368, 371, 372, 375, 377 Timer Fail RAP
116-364 An error in the timer was detected.
116-365 Fatal error of the SPL.
116-366 Print utility operational failure, report generator operational failure.
116-368 Fatal error of DumpPrint.
116-371 PCL decomposer software failure.
116-372 Fatal error of P-formatter.
116-375 A response such as system function recall error was detected.
116-377 Video DMA failure was detected.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
PL 3.10
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Ensure that all connectors on the drive PWB,
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3.
Reload the software,
GP
4.
Perform the
OF2
Special Boot Modes RAP.
April 2017
116-355, 363, 367, 370, 373, 376, 116-364, 365, 366,
2-511
WARNING
GP
10. Disconnect the power cord. Electricity can cause
GP
10.
PL 1.10 Item 3
and the ESS PWB,
4.
PL 3.10
Status Indicator RAPs