041-388, 041-391 Logic Fail RAP
041-388 When fatal abnormality was detected in marking control.
041-391 Finisher module fatal error was detected.
Procedure
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Reload the software,
GP
4.
Status Indicator RAPs
041-388, 041-391, 041-603, 041-604
GP
10.
041-603, 041-604 Environment Sensors Fail RAP
041-603 The value of the temperature sensor exceeds the upper limit.
041-604 The value of the humidity sensor exceeds the upper limit.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Ensure that the fusing unit exhaust fan and the marking unit fan are operating correctly,
refer to:
•
042-330
Fuser Exhaust Fan Fail RAP.
•
043-344
Marking Fan Fail RAP.
3.
If the fault persists, install a new ESS PWB,
NOTE: The temperature sensor and humidity sensor are both surface mounted on the
ESS PWB.
April 2017
2-446
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10. Disconnect the power cord. Electricity can cause
GP
10.
PL 3.10 Item
6.
Launch Issue