2. Replace the operator information panel cable.
3. Replace the operator information panel.
• 806f001e-2201ffff : No bootable media available for system [ComputerSystemElementName]. (No
Boot Device)
This message is for the use case when an implementation has detected a System with No Bootable
Media.
May also be shown as 806f001e2201ffff or 0x806f001e2201ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0286
User Response
No action; information only.
• 806f0021-2201ffff : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (No Op ROM Space)
This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00212201ffff or 0x806f00212201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0330
User Response
1. Check the PCI LED.
2. Reseat the affected adapters and riser card.
3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
544