This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
May also be shown as 800102041d08ffff or 0x800102041d08ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat rear hdd cage riser n.
2. Remove the following component and identify the problem. a. HDD drive b. HDD cable c. RAID
card d. cage riser n
3. Replace rear hdd cage riser n (n = riser number).
• 80010204-1d09ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan Riser2A Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
May also be shown as 800102041d09ffff or 0x800102041d09ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat rear hdd cage riser n.
2. Remove the following component and identify the problem. a. HDD drive b. HDD cable c. RAID
card d. cage riser n
3. Replace rear hdd cage riser n (n = riser number).
446
Lenovo System x3650 M5 Installation and Service Guide