Lenovo System x3650 M5 Installation And Service Manual page 517

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions in "Power Problems and Solving Power Problems".
4. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Replace power supply n. (n = power supply number)
PS1 12V OV Fault : PS1 12V UV Fault : PS1 12Vaux Fault :
• 80070608-0a02ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (PS2 12V
OC Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706080a02ffff or 0x800706080a02ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is solved:
1. Use the Lenovo Power Configurator utility to determine current system power consumption. For
more information and to download the utility, go to https://www.ibm.com/support/entry/
myportal/docdisplay?lndocid=LNVO-PWRCONF.
2. Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions in "Power Problems and Solving Power Problems".
4. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
Appendix A. Integrated management module II (IMM2) error messages
505

Advertisement

Table of Contents
loading

Table of Contents