Lenovo System x3650 M5 Installation And Service Manual page 492

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0520
User Response
1. Check the microprocessor installed is Intel E5-2690.
2. Reduce the ambient temperature under 27 Celsius degree.
• 80070101-2c01ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (ML2 OverTemp)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
May also be shown as 800701012c01ffff or 0x800701012c01ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0520
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear
of the server), that the air baffle is in place and correctly installed, and that the server cover is
installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Replace the failed ML2 card.
• 8007010d-2582ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (RAID Vol State)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
May also be shown as 8007010d2582ffff or 0x8007010d2582ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
480