Lenovo System x3650 M5 Installation And Service Manual page 188

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

• You can install one 2.5-inch simple-swap SATA hard disk drives in bay 0 in the server. Do not install hot-
swap drives into a simple-swap server model, it is not supported.
• The simple-swap server models are available only in non-RAID configurations.
• The electromagnetic interference (EMI) integrity and cooling of the server are protected by having all bays
and PCI Express slots covered or occupied. When you install a drive or a PCI Express adapter, save the
EMC shield and filler panel from the bay or PCI Express adapter slot cover in the event that you later
remove the device.
To install a simple-swap hard disk drive, complete the following steps:
Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines" on page
305.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the filler panel from the empty drive bay.
Step 4.
Touch the static-protective package that contains the drive to any unpainted metal surface on the
server; then, remove the drive from the package and place it on a static-protective surface.
Step 5.
Install the hard disk drive in the drive bay. Align the drive assembly with the guide rails in the bay
and gently push the drive into the bay until the drive stops.
2.5-inch simple-swap
hard disk drive
Figure 95. 2.5-inch simple-swap hard disk drive installation
3.5-inch simple-swap
hard disk drive
Figure 96. 3.5-inch simple-swap hard disk drive installation
Step 6.
Reinstall the drive bay filler panel that you removed earlier, if needed.
Step 7.
If you are installing additional simple-swap hard disk drives, do so now.
176
Lenovo System x3650 M5 Installation and Service Guide
Filler panel handle
Filler panel

Advertisement

Table of Contents
loading

Table of Contents