2. Replace power supply n. (n = power supply number)
PS2 12V OV Fault : PS2 12V UV Fault : PS2 12Vaux Fault :
• 80070614-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (TPM Phy
Pres Set)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706142201ffff or 0x800706142201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
1. Update the server firmware (see Recovering the server firmware).
2. If the problem persists, (trained technician only) replace the system board (see Removing the
system board and Installing the system board).
• 80070625-2583ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (X8 PCI 1
Config)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706252583ffff or 0x800706252583ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
None X8 PCI 2 Config : X8 PCI 6 Config : X8 PCI 7 Config :