4. Replace the power supply with higher rated power if Oversubscription_Fault seen in power
supply.
5. Please reseat power cords and power supplies.
• 800b050a-1e81ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted. (Fan Zone 1)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050a1e81ffff or 0x800b050a1e81ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4. Reseat the fans.
5. Replace the fans. (n = fan number)
• 800b050a-1e82ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted. (Fan Zone 2)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050a1e82ffff or 0x800b050a1e82ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Appendix A. Integrated management module II (IMM2) error messages