Lenovo System x3650 M5 Installation And Service Manual page 456

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
Fan 4B Tach :
• 80010204-1d05ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan 5A Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
May also be shown as 800102041d05ffff or 0x800102041d05ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
Fan 5B Tach :
• 80010204-1d06ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan 6A Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.