Lenovo System x3650 M5 Installation And Service Manual page 504

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-
supply fan.
2. Use the Lenovo Power Configurator utility to ensure current system power consumption is under
limitation. For more information and to download the utility, go to https://www.ibm.com/support/
entry/myportal/docdisplay?lndocid=LNVO-PWRCONF.
3. Replace power supply n. (n = power supply number)
• 8007020c-2585ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (nvDIMM Status)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020c2585ffff or 0x8007020c2585ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
None
• 8007020d-2582ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (RAID Vol State)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020d2582ffff or 0x8007020d2582ffff
492
Lenovo System x3650 M5 Installation and Service Guide