Symptom
The Pwr rail A error has been
recorded in the system event
log.
The Pwr rail B error has been
recorded in the system event
log.
The Pwr rail C error has been
recorded in the system event
log.
96
Lenovo System x3650 M5 Installation and Service Guide
http://www.lenovo.com/support
Action
1. Disconnect the server power cords.
2. (Trained technician only) remove microprocessor 1 if the Pwr rail A error has
been recorded in the system event log.
3. (Trained technician only) replace the system board (see "Removing the system
board" on page 299 and "Replacing the system board" on page 302).
4. Reinstall the component; then, restarting the server. If the Pwr rail A error has
been recorded in the system event log again, the component that you just
reinstalled is defective. Replace the defective component.
• (Trained technician only) Microprocessor 1 (see "Removing a microprocessor
and heat sink" on page 284 and "Replacing a microprocessor and heat sink"
on page 289).
1. Disconnect the server power cords.
2. Remove DIMMs 1 through 12 if Pwr rail B error has been recorded in the system
event log.
3. Restart the server. If the Pwr rail B error has been recorded in the system event
log again, (trained technician only) replace the system board (see "Removing
the system board" on page 299 and "Replacing the system board" on page
302).
4. Reinstall the DIMM one at a time, restarting the server each time. If the Pwr rail
B error has been recorded in the system event log again, the DIMM that you just
reinstalled is defective. Replace the defective component.
1. Disconnect the server power cords.
2. (Trained technician only) remove microprocessor 2 if Pwr rail C error has been
recorded in the system event log.
3. Restart the server. If the Pwr rail C error has been recorded in the system event
log again, (trained technician only) replace the system board (see "Removing
the system board" on page 299 and "Replacing the system board" on page
302).
4. Reinstall the Processor; then, restarting the server. If the Pwr rail C error has
been recorded in the system event log again, the Processor that you just
reinstalled is defective. Replace the defective component.
• (Trained technician only) Microprocessor 2 (see "Removing a
microprocessor and heat sink" on page 284 and "Replacing a
microprocessor and heat sink" on page 289).