No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0524
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server each
time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive
backplane (n = hard disk drive number)
• 80070608-0a01ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (PS1 12V
OC Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706080a01ffff or 0x800706080a01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is solved:
1. Use the Lenovo Power Configurator utility to determine current system power consumption. For
more information and to download the utility, go to https://www.ibm.com/support/entry/
myportal/docdisplay?lndocid=LNVO-PWRCONF.
2. Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved: