Removing the Incoming Water Solenoid

For this procedure the processor must be deenergized. See page 1-7. In addition, the
FEED-END, LOWER ACCESS PANEL must be removed from the processor. See pages 1-3
through 1-5 for instructions, if necessary. Also make sure that the water supply to the processor
is shut off for this procedure.
[1]
Disconnect the SPADE CONNECTORS.
[2]
Loosen the HOSE CLAMP.
[3]
Remove the HOSE and disconnect the INCOMING WATER CONNECTION.
[4]
Remove the 2 SCREWS.
[5]
Remove the INCOMING WATER SOLENOID from the processor.
[6]
Install the new INCOMING WATER SOLENOID.
[7]
Install all parts removed in previous steps and make the necessary connections.
SCREWS
246616
INCOMING
WATER
CONNECTION
Figure 5-24 Removing the Incoming Water Solenoid