Daily Care

Reliable operation of the processor requires that all parts are cleaned, adjusted, and lubricated correctly.
Report any change in the operating condition of the processor to your service personnel.
Wear rubber gloves, safety glasses, and protective clothing when doing these maintenance
procedures. See pages 1-3 through 1-7 if necessary.
Handle assemblies carefully to prevent changing their alignment. Do not clean the RACKS,
CROSSOVER ASSEMBLIES, or SQUEEGEE ROLLERS using abrasive materials. Do not wash
the ROLLER or RACK ASSEMBLIES with water hotter than 100°F (37.5°C).
[1]
Remove the EVAPORATION COVERS, DEVELOPER/FIXER CROSSOVER, FIXER/WASH
CROSSOVER, and SQUEEGEE ASSEMBLIES. Clean the parts with warm water and a damp cloth.
Dry all the parts with a clean cloth, or allow the parts to air dry.
FILTER BEZEL
SPLASH GUARD
7-2
NOTE
Figure 7-1 Location of Assemblies
EVAPORATION
COVERS
H108_0055BCC
H108_0239BA
246616