Removing The Replenishment Control Valves - Kodak X-Omat 480 RA Service Manual

Hide thumbs Also See for X-Omat 480 RA:
Table of Contents

Advertisement

Removing the Replenishment Control Valves

For this procedure the processor must be deenergized. See page 1-7. In addition, the
RECEIVING-END ACCESS PANEL must be removed from the processor. See pages 1-3
through 1-5 for instructions, if necessary. Also make sure that the water supply to the processor
is shut off for this procedure.
[1]
Place a CLAMP TL-2170 on the input and output HOSES of the REPLENISHMENT CONTROL VALVE
to be removed.
[2]
Loosen the HOSE CLAMPS and remove the HOSES from the REPLENISHMENT CONTROL VALVE.
[3]
Remove the HANDLE from the REPLENISHMENT CONTROL VALVE.
[4]
Remove the SCREW securing the BRACKET to the REPLENISHEMENT CONTROL VALVE.
[5]
Remove the REPLENISHMENT CONTROL VALVE from the processor.
[6]
Install the new REPLENISHMENT CONTROL VALVE.
[7]
Install all parts removed in previous steps and make the necessary connection.
[8]
Remove the CLAMP TL-2170 from the INPUT and OUTPUT HOSES.
FIXER REPLENISHMENT
CONTROL VALVE
5-26
HOSE
CLAMPS
BRACKET
Figure 5-23 Removing the Replenishment Control Valves
IMPORTANT
SCREW
DEVELOPER REPLENISHMENT
CONTROL VALVE
H108_0045BCB
H108_0045BA
246616

Advertisement

Table of Contents
loading

Table of Contents