Removing an EMI Line Filter

For this procedure the processor must be deenergized. See page 1-7. In addition, the
FEED-END, LOWER ACCESS PANEL must be removed from the processor. See pages 1-3
through 1-5 for instructions, if necessary.
[1]
Remove the WIRES at the EMI LINE FILTER 1, 2, 3, or 4 (EMI LINE FILTER 3 is not shown.)
Identify line and load labeling so that you can connect the WIRES to the new EMI LINE FILTER
in their correct orientation.
[2]
Remove and keep the 4 SCREWS securing the EMI LINE FILTER.
[3]
Remove the EMI LINE FILTER.
[4]
Reverse the above procedure to install a new EMI LINE FILTER.
EMI LINE FILTER (FL1)
6-26
IMPORTANT
SCREW (4)
Figure 6-19 Removing EMI Line Filters