Removing the O-Ring from the Recirculation Pump

For this procedure the processor must be deenergized. See page 1-7. In addition, the DRIVE
SIDE ACCESS PANEL must be removed from the processor. See pages 1-3 through 1-5 for
instructions, if necessary.
[1]
Place a CLAMP, TL-2170, on the input and output TUBES of the PUMP to prevent leakage of solution.
[2]
Remove:
• 4 WING NUTS
• OUTER PUMP HOUSING
• O-RING SEAL.
[3]
Install a new O-RING SEAL.
[4]
Install all parts removed in previous steps.
[5]
Remove the CLAMP from each of the TUBES.
246616
IMPORTANT
THRUST
WASHER
Figure 5-2 Removing the O-Ring Seal
CUP MAGNET
INNER
HOUSING
O-RING
SEAL
IMPELLER
OUTER
PUMP HOUSING
SCREW
WING
NUT (4)
H108_0040DCB
H108_0175DA
5-3