Regular Inspections

To maintain the V530-R160 in the best condition, perform the following regularly.
 Clean the Lens and LED indicators with a lens-cleaning wipe or blow off dust with an aerosol air
sprayer.
 Lightly wipe off dirt with a soft cloth.
Inspection point
Power supply
The voltage measured at the power supply terminals on
the terminal block must be 20.4 VDC to 26.4 VDC.
Ambient temperature
The operating ambient temperature inside the cabinet
must be between 0 to 50°C.
Ambient humidity
The operating ambient humidity inside the cabinet must be
between 35 and 85%.
Installation
Each cable connector must be correctly inserted and
locked.
The cameras must be firmly secured.
The camera lens mounts must be firmly secured.
LED lights
All indicators must light when the power is turned ON.
• Verify that a through-image is displayed.
• When using an Intelligent Lighting, verify that the light
• Turn OFF the power and take safety precautions before conducting inspections.
• Do not use thinners or benzene.
Details
level settings are set to their maximum values.
SECTION 10
Appendix
Tools required
Circuit tester
Thermometer
Hygrometer
Screwdriver
V530-R160