SECTION 8
Communication with the Host
 Flow Control Settings
Set the flow control and timeout time when communicating in the Normal mode with a host such
as a personal computer.
1.
Select Normal on the communications speci-
fications setting screen.
The Normal setting screen will be displayed.
2.
Make the settings for each item.
3.
Select End.
The setting will be registered and the screen in
.
Set Items and their details
Item
Flow control
Timeout
The asterisk (*) indicates the default setting.
Flow control
Communications are carried out while checking the status of the host. If there is no response from
the host for longer than the set timeout time, a timeout error occurs, and an error message is dis-
played on the screen.
The parallel I/O error signal also turns ON.
V530-R160
208
Operation Manual
1.
will return
None*
No flow control is performed.
Xon/Xoff
The software performs flow control. Data is transmitted in
accordance with the Xon/Xoff code sent from the host.
Set the number of seconds (1 to 120 seconds) before a timeout error occurs.
(1 to 120 s; default setting: 5 s)
Selection
If using the save and load commands (@CS, @CL,
etc.), select None.