The setting will be registered and the System mode screen will return.
The stored images are cleared when the power is turned OFF.
The images must be backed up in the computer or in a Memory Card if you want to save them long
term.
Refer to page 149 (Sec.6).
 Image Storage Conditions
The V530-R160 can save up to 35 read images (Same for all scenes). The condition for saving
the images can be selected as "saved only when the reading judgement is NG" or "all images
saved regardless of the reading judgement." When 35 images have been stored, new images will
be stored by overwriting old images, starting with the oldest.
Previous 4
Product line
Saved image
When the setting
is for NG images
only to be saved.
When the setting
is for all images
to be saved.
Previous 4
Even if Only NG is set as the image storage condition, the latest read image is saved.
Reading can be repeated for stored images.
Display the desired stored image using the SHIFT + Up/Down Keys and press the SHIFT + TRIG
Keys to execute reading.
Reading can also be repeated for freeze images without re-inputting the image using the SHIFT +
TRIG Keys. By reading an image again after adjusting the reading conditions, you can check if the
conditions are appropriate.
Previous 3
Previous 2
NG
OK
Previous 2
Previous 3
Previous 2
System Settings
Previous 1
Latest object
NG
OK
Previous 1
Previous 1
SECTION 7
OK
Latest
Latest
V530-R160
183