Omron V530-R160E User Manual page 222

2d code reader
Hide thumbs Also See for V530-R160E:
Table of Contents

Advertisement

SECTION 8
Communication with the Host
@ MC
Function • • • Changes the mode to MON (monitor) mode or RUN mode.
Send
Receive
@ MT
Function • • • Reads the most recent read-processing time.
Send
Receive
V530-R160
220
Operation Manual
@
M
C
Set the mode to 0 to specify MON mode or 1 to specify RUN mode.
Command executed correctly:
<Header>
O
K
Command not executed correctly:
<Header>
E
R
@
M
T
<Footer>
Command executed correctly:
<Processing time>
<Header>
The 5-digit processing time (00000 to 99999 ms) is returned if the command was
executed correctly.
A value of 99999 will be returned if the actual processing time exceeds 99,999 ms.
A value of 00000 will be returned if the processing time could not be read.
Example: A value of 00230 will be returned when the most recent processing time
was 230 ms.
<Mode>
<Footer>
<Footer>
<Footer>
<Footer>