SECTION 9
Appendix

Handling Reading Heads

The Camera and Reading Head are optical components. Handle them with care.
Images will be negatively affected if the Reading Head or Camera is dirty or cracked,
possibly preventing reading.
• Do not touch the lens, mirror surface, or surface of the lighting cover with your fingers
or any pointed object.
• Use the Reading Head in an environment free of dust. If the lens, mirror surface, or
surface of the lighting cover becomes dirty, use a lens cloth or air brush to clean
them.
• When mounting the Reading Head to the Camera, do not touch the imaging surface
of the CCD on the Camera or get it dusty.
p.104

Regular Inspections

To maintain the V530-R2000 in the best condition, perform the following regularly.
• Clean the Lens and LED indicators with a lens cloth or blow off dust with an air brush.
• Lightly wipe off dirt with a soft cloth.
Inspection point
Power supply
Ambient operating
temperature
Ambient operating
humidity
Installation
· Turn OFF the power and take safety precautions before conducting inspections.
· Do not use thinners or benzene.
V530-R2000
114
User's Manual
The voltage measured at the power supply terminals on the termi-
nal block must be between 20.4 VDC and 26.4 VDC.
The ambient operating temperature inside the cabinet must be
between 0 and 50 ° C.
The ambient operating humidity inside the cabinet must be
between 35% and 85%.
Each cable connector must be correctly inserted and locked.
The Cameras must be firmly secured.
The camera lens mounts must be firmly secured.
Details
Tools required
Circuit tester
Thermometer
Hygrometer
Screwdriver