SECTION 9
Troubleshooting
Error code
E150
E200
 DataMatrix explanatory diagram
3.
V530-R160
254
Operation Manual
Description
Decode Error
(No definition error)
Timeout Error
2.
(X direction)
4.
1.
A margin of 1 or more cells around the code is required.
2.
Timing patterns (The cross point between black and white.)
3.
The L-shape in the corner is a finder pattern.
4.
An area other than 1 to 3 contains the data.
Countermeasures
The printing is in a special format and not
defined for the V530-R160.
• Change the printing format.
Decoding was not performed within the time-
out time.
• Make the reading angle in Pattern set-
tings/Code settings smaller.
• Lengthen the Reading settings/Timeout.
• Change the angle of vision, e.g. by increas-
ing the size of the code image.
1.
2.
(Y direction)
p.108