Omron V530-R160E User Manual page 200

2d code reader
Hide thumbs Also See for V530-R160E:
Table of Contents

Advertisement

SECTION 8
Communication with the Host
 Continuous Reading (When Trigger Mode is [Level Trigger])
 When the reading is performed correctly:
RUN
TRIG B
TRIG C
TRIG D
BUSY
OK/NG
GATE
(RS-232C)
Output signal
The function of the signal is the same as for continuous reading (when the trigger mode is set to [Continu-
ous Reading]).
Input signal
Signal
TRIG B
TRIG C
TRIG D
V530-R160
198
Operation Manual
Enter RUN mode.
OFF
ON
OFF
ON
Note: A delay of 33.3 ms max. occurs before starting to read images
after the TRIG B signal is turned ON.
OFF
ON
Perform reading.(OK)
OFF
ON
Gate ON delay
Note: The output time to RS-232C changes depending on the data volume and
baud rate.
Repeats reading until an OK (readable) reading judgement is output while the TRIG B ter-
minal is ON.
Repeats reading until an OK (readable) reading judgement is output while the TRIG C ter-
minal is ON.
Repeats reading until an OK (readable) reading judgement is output while the TRIG D ter-
minal is ON.
Judgement (OK)
Gate ON time
Output period
Function
Leave RUN mode.

Advertisement

Table of Contents
loading

This manual is also suitable for:

V530-r160ep

Table of Contents