SECTION 8
Communication with the Host
Settings at the Programmable Controller
• Turn OFF DIP switch 5 of CQM1H.
• Set the communications conditions.
Set DM6645 to 1001, DM6646 to 0904, DM6648 to 1000 and DM6649 to 0D00.
Refer to the operation manual for CQM1H for the ways to change the setting.
• Set the read command.
Set DM0100 to 4047 and DM0100 to 4C00.
Communications method
Baud rate
Data length
Parity bits
Stop bits
Header
Footer
Settings at the Controller
Make the following communication settings.
Baud rate
Data length
Parity bits
Stop bits
Header
Footer
FCS
Mode
V530-R160
230
Operation Manual
Item
Item
The same settings as those of
the Programmable Controller.
Setting
Normal
9600 bps
7 bit
EVEN
2 bit
None
CR
Setting
OFF
Normal