SECTION 6
Other Functions

Backing Up to Flash Memory

The scene data and system data will be saved to the V530-R160 internal flash memory.
Flash memory data or Memory Card data is loaded each time the V530-R160 is started up. There-
fore, when settings have been changed, be sure to save to flash memory before turning the power
OFF. Any new data will be lost if it is not saved to flash memory.
1.
The MON (monitor) mode or RUN mode
screen will be displayed.
2.
Move the cursor to MON or RUN and press
the ENT Key.
The mode selections will be displayed.
3.
Select SAVE.
The confirmation message will be displayed.
4.
Select Execute.
Never input the RESET signal or turn OFF the power when processing messages are displayed.
Data may be lost, and the V530-R160 may not operate properly the next time it is started.
When saving has been completed, the screen in
V530-R160
150
Operation Manual
1.
will return.