Set Items and their details
Item
Read area
Begin read word
Write area
Begin write word
PLC mode check
The asterisk (*) indicates the default setting.
Select the relay where the controller checks commands.
I/O*, HR (holding relay), LR (link relay), DM (data memory), None (No
reading. TXD instruction will be accepted.)
Set the first word to read in area specified above.
(0 to 9995; default setting: 0)
Select the relay where the controller outputs execution results.
I/O*, HR (holding relay), LR (link relay), DM (data memory), None (No
writing)
Set the first word to write in the area specified.
(0 to 9996; default setting: 100)
ON*
On entering the MON mode or RUN mode, the mode of the pro-
grammable controller is checked. Reading does not start unless
the programmable controller is in MON mode.
(Error messages are displayed.)
OFF
When the V530-R160 is in MON or RUN mode, it sends a mode
change command to the Programmable Controller to forcibly
switch the Programmable Controller to MON mode.
Communication with the Host
Selection
SECTION 8
V530-R160
239
Operation Manual